Seitenansicht 0
M165920S
Owner’s Manual
Instructions for Installation/Set-up, Operation, Servicing, & Storage
Portable, Outdoor Use-Only, Industrial Gasoline Generator
6,600 Watt Continuous (8,000 Watt Surge) Capacity
Can be used to power individual appliances plugged directly into the generator’s outlets, or as a back-up
connection to a building’s power supply (via a professionally installed UL-approved transfer switch.
WARNING
READ and UNDERSTAND this manual completely before using the generator! Failure to properly set up,
operate, and maintain this generator could result in serious injury or death from carbon monoxide poisoning,
electric shock, fire/explosion, or burns. In particular, be aware of the following hazards:
CO Poisoning
Generators give off carbon monoxide, a poisonous gas that can kill you. You CANNOT smell it, see it, or taste it.
ONLY run generator OUTDOORS and AWAY from building air intakes. NEVER run generator inside any enclosed or
semi-enclosed spaces, including homes, basements, garages, sheds, boxes, RVs, boats or pick-up truck beds. These
spaces can trap poisonous gases, EVEN if you run a fan or open windows.
Install carbon monoxide alarms inside nearby structures/buildings (battery-operated, or plug-in with battery backup).
Electric shock / Electrocution
High voltage electricity from generator can kill. DO NOT operate in wet locations. Be sure generator is properly
grounded. Use only UL-listed, outdoor-rated grounded extension cords of proper size.
NEVER plug the generator directly into a wall outlet. ANY connection to a building’s electrical system MUST
ISOLATE THE GENERATOR FROM UTILITY POWER via a UL-approved transfer switch installed by a licensed
electrician. Otherwise, back feed from the generator into the power grid could kill utility workers.
Fire / Explosion
DO NOT overload generator (per rated capacity), and OPERATE ONLY in an area with adequate cooling ventilation so
engine does not overheat. Exhaust can be extremely hot. Keep muffler at least 7’ from all combustible objects.
All fuels are flammable. Never fuel a running or hot engine. Never pump fuel directly into generator at gas station – use
approved container to transfer fuel. Ensure there are no fuel leaks, and keep sources of sparks and flames away.
ALWAYS keep a fire extinguisher rated “ABC” nearby.
STOP!
CHOOSE THE RIGHT GENERATOR FOR YOUR NEEDS. See the “Power load Planning & Management” section
of this manual to determine your power load requirements and then compare to the generator’s rated capacity.
INSPECT COMPONENTS: Closely inspect to make sure no components are missing or damaged. See the “Unpacking
& Delivery Inspection” section for instructions on whom to contact to report missing or damaged parts.
ARRANGE FOR PROFESSIONAL INSTALLATION of a transfer switch if you will be connecting the generator
to your building’s electrical system. See the “Installation/Initial Set-Up” section for more information about this
requirement.
Any Questions, Comments, Problems, or Parts Orders
Call NorthStar Product Support 1-800-270-0810
ITEM NUMBER: 165920
SERIAL NUMBER: _____________
®
Seitenansicht 0
1 2 3 4 5 6 ... 43 44

Inhaltsverzeichnis

Seite 1 - M165920S

M165920S Owner’s Manual Instructions for Installation/Set-up, Operation, Servicing, & Storage Portable, Outdoor Use-Only, Industrial Gasolin

Seite 2

Power Load Planning & Management 10 WARNING NEVER exceed the rated wattage capacity of you

Seite 3 - Table of Contents

Power Load Planning & Management (cont’d) 11 Device Running Watts Device Running Watts Furnace fan (1/3 HP) 1200 (a) Submersible pump (1-1/

Seite 4 - About Your Generator

Installation / Initial Set-Up 12 There are a number of important steps required to set up your gen

Seite 5 - ATTENTION:

Installation / Initial Set-Up 13 3. Set-up either as a BUILDING BACK-UP or PORTABLE Power Source This generator is designed to provide up to 8000

Seite 6 - SPECIFICATIONS

Installation / Initial Set-Up 14 The generator cannot power your entire home -- you must work with the installing electrician to determine which d

Seite 7 - Safety Label Locations

Installation / Initial Set-Up 15 ♦ Make sure you plug each electrical device/appliance into the correct generator outlet based on the device’s pl

Seite 8

Installation / Initial Set-Up 16 4. Select a Suitable Site Before using the generator, you must select a suitable OUTDOOR location for installatio

Seite 9 - REFERENCE GUIDE

Installation / Initial Set-Up 17Adequate cooling ventilation The generator needs adequate, unobstructed flow of air to allow for proper cooling of

Seite 10 - WARNING

Installation / Initial Set-Up 1810 Ga. wireCopperPipe/RodGrounding Post Ground 5. Grounding the generator Always ensure the generator is properly

Seite 11

Installation / Initial Set-Up 19 6. Battery Installation Your generator’s engine is equipped with an electric starter which requires the installa

Seite 12 - 2. Planning the Power Load

Hazard Signal Word Definitions 2

Seite 13

Operation 20 Once you have set up your generator for use, it is time to start your generator. Th

Seite 14 - RECEPTACLES

Operation (cont’d) 21• Malfunction during operation. Immediately turn off the generator if any of the following conditions arise during operatio

Seite 15

Operation (cont’d) 22 Static electricity and filling the gasoline tank: Static electricity can initiate from ungrounded gasoline tanks or containe

Seite 16 - 4. Select a Suitable Site

Operation (cont’d) 23 2. Preparing for Operation Position generator Position generator in accordance with the instructions given in “Installation

Seite 17

Operation (cont’d) 24 WARNING: Gasoline fire/explosion hazard Gasoline is highly flammable and explosive. Heat, sparks, and flame

Seite 18 - 5. Grounding the generator

Operation (cont’d) 25vehicle, trailer, trunk, or pick-up truck bed. ALWAYS place container on the ground to be filled. • Keep nozzle in conta

Seite 19 - 6. Battery Installation

Operation (cont’d) 26 3. Starting the Engine After you have completed the pre-start checklist procedures, you are ready to start the engine. To

Seite 20 - Operation

Operation (cont’d) 27 4. Checking Generator Output Although the speed of the engine was carefully adjusted at the factory so that the generator p

Seite 21 - Operation (cont’d)

Operation (cont’d) 28 5. Connecting Loads You will want to be careful when connecting loads so as not to overload the generator, especially if yo

Seite 22

Operation (cont’d) 29 7. Storage & Exercise When you are finished using the generator, you must: o Disconnect all loads o Shut off fuel su

Seite 23

Table of Contents 3 Hazard Signal Word Definitions ...

Seite 24

Operation (cont’d) 30Prepare engine for long term storage if needed If you will not be able to exercise the generator regularly, you must prepare

Seite 25

Maintenance & Repair 31 Inspect and maintain your generator as specified below in order to ke

Seite 26

Maintenance & Repair (cont’d) 32Inspect fuel system / check for leaks Inspect the fuel system and check for leaks on a regular basis. Inspect

Seite 27

Troubleshooting 33 TROUBLESHOOTING Problem Possible Causes Possible Remedies Engine wi

Seite 28

Summary of Important Safety Information for Operation 34 This section provides a summary of the v

Seite 29

Summary of Important Safety Information for Operation (cont’d) 35 Installation / Initial Set-up Safety • Dry, level surface. Situate generator on

Seite 30

Summary of Important Safety Information for Operation (cont’d) 36• Use approved container. Never pump fuel directly into engine at gas station.

Seite 31 - Maintenance & Repair

Summary of Important Safety Information for Operation (cont’d) 37• Hot muffler. Never touch hot muffler, hot exhaust manifold, or engine cooling

Seite 32

Exploded View Rev - S 38

Seite 33 - TROUBLESHOOTING

Exploded View Rev - S 39 Diag # Part # Description Qty 1 38759 Fuel Tank Assembly 1 2 33321

Seite 34 - General

About Your Generator 4 Thank you for purchasing your NorthStar portable generator! About Your Ge

Seite 35 - Safety – Before Use

Wiring Diagram Rev - S 40

Seite 36 - Safety – During Use

Wiring Diagram Rev - S 41 Diag # Part # Description Qty1 31344 GFCI Duplex Receptacle, NEMA 5-

Seite 37 - Safety – After use

Generator Head Exploded View Rev - S 42 Item # Part # Descr

Seite 38 - Exploded View Rev - S

Limited Warranty 43 Dear Valued Customer: The NorthStar Product you just purchased is built with

Seite 39

44 Manufactured by Northern Tool + Equipment Co

Seite 40 - Wiring Diagram Rev - S

About Your Generator (cont’d) 5NorthStar is constantly improving its products. The specifications outlined herein are subject to change without p

Seite 41

Specifications 6 SPECIFICATIONS Item Number 165920 Maximum Output 8000 Watts (W) Continuous Out

Seite 42

Safety Label Locations 7 Always make sure safety labels are in place

Seite 43 - Limited Warranty

Machine Component Identification - Item #165920S 8 Figure 1 (Ref. 1-13) Ref.

Seite 44

Machine Component Identification - Item #165920S 9REFERENCE GUIDE Reference 1 – Air Cleaner Refer to your Honda engine manual for air cleaner care

Kommentare zu diesen Handbüchern

Keine Kommentare